Water Pump
(95)
Electric Motor
(32)
Generator
(176)
Reason:
1. Pump shell with air, irrigation pumps do not work
2. Suction pipe and filling with gas leakage
3.Water Pump does not turn
4.Water Pump speed too low
5. Impeller inlet and the flow channel block
6. At the end of valve blockage or leakage
7. Suction water level decline in wells, Water Pump installation height too
8. Less leakage and impeller wear ring
9. Surface of the water generated swirl, air into the pump
10. Seal pipe plug
Remedy:
1. To continue to irrigation or ventilation
2. Plug leaks, adequate padding pressed
3. Right for a pair of wiring, changing the steering
4. Check the circuit if voltage is too low
5. Opened a pump cover, remove debris
6. Remove debris or repair of
7. Accounting suction height, and thinking that when you reduce the installation height
8. Replacement of worn parts
9. Increase the suction mouth flooded depth or to take preventive measures
10. Kiyomichi removed