Fault:
Water Pump to open or activate the rear axle does not move too much power
Reason:
1. Packing way too dead, shaft bending, bearing wear
2. Multi-stage pump to plug holes in balance or re-pipe plug
3. Back wheel gap is too small, the operation of two-axis relative to the top
4. Voltage is too low
5. The actual design of the liquid is much larger than the proportion of the proportion of the liquid
6. Flow too much, over use of too much
Address:
1. Song 1:00 gland, shaft straightening, replacing bearings
2. Remove debris, clear backwater pipe
3. Backrest adjustment gap
4. Check the circuit to the power situation partly reflects the
5. To replace electric motors, increased power
6. GUAN Xiao-water valve